Mapping TestArchitect test cases to Quality Center tests

Mapping TestArchitect test cases to Quality Center tests allows for the execution of those test cases to be directed from Quality Center.

Ensure that the machine hosting the TestArchitect repository server has the HP ALM Connectivity Add-in installed, to allow for integration and synchronization between TestArchitect and HP Quality Center.

Ensure that you have already taken the following steps:

To map TestArchitect test cases to Quality Center tests:

  1. In the TestArchitect explorer tree, right-click the node of a test module (either default or non-default variation) containing the test cases to be mapped, or a test folder, or the Tests node itself, and then click External Tool > HP ALM > Map Test Cases.

    As you may guess, the higher the level of the node you click, the “wider the net” you cast for eligible test cases.

    The Map Test Cases dialog box is launched, displaying a list of all TestArchitect test cases falling within scope of the clicked node.

  2. In the list of test cases, for each test case that you wish to have mapped to a Quality Center test, enter the Quality Center Test ID into the Source column.

    重要: 
    • For each mapping, the Quality Center test must already exist, and must have its Type field set to the value VAPI-XP-TEST .
    • Mappings between TestArchitect test cases and Quality Center tests are restricted to a 1-to-1 basis. (That is, one-to-many mappings are not permitted.)
  3. Click OK.

    注意: 
    If your user name has not already been authenticated by Quality Center for the current session, you will be prompted to enter the password for the account.

    • If any of the selected Quality Center tests are already mapped to other TestArchitect test cases, the dialog box remains in place, and the source IDs of those tests are displayed in red.

      • In order to see which TestArchitect test case is currently associated with a given Quality Center test, click the red source ID.
      • In each case, enter a different Quality Center Test ID, then click OK.
    • If any problems occur during the test case mappings, a dialog box appears listing the test cases that could not be mapped to Quality Center. Close it, try and resolve the problem, and try again.

Successfully mapped test cases may be viewed in Quality Center.


Copyright © 2024 LogiGear Corporation. All rights reserved. LogiGearはLogiGear Corporationの登録商標であり、Action Based TestingおよびTestArchitectはLogiGear Corporationの商標です。ここに記載されているその他の商標は、各所有者の財産です。

LogiGear Corporation

1730 S. Amphlett Blvd. Suite 200, San Mateo, CA 94402

Tel: +1 (650) 572-1400