is control focused
Return a Boolean value to indicate whether the specified control has focus.
Name | Description | Type | Modifier |
---|---|---|---|
window | TA name of the window. | Interface Entity | None |
control | TA name of the control. | Interface Element | None |
variable | (Optional) Variable to receive the returned Boolean value. Possible returned values:
| String | None |
Value to indicate whether the specified control has focus.
This action may be used within the following project items: test modules and user-defined actions.
This action is applicable to the following controls: button, check box, checklist, combo box, datetime, list box, menu, password, radio button, richtext, separator, spin, tab control, table, text box, toggle button, toolbar, trackbar, tree view.
interface
use interface Car Rental
 
window control variable
is control focused login user name i
- variable argument:
- If the variable in argument variable has not been declared, the action creates it as a global.
- If the variable argument is left empty, TestArchitect supplies a global variable with the name _result.
- This action supports the <ignore> modifier. If the string
<ignore>
is present as the value of any of the arguments, or any argument contains an expression that evaluates to<ignore>
, the action is skipped during execution.